Measurments related to lead III in the 10s resting ECG
28 variables.
-
Duration P Wave, III
Duration of P Wave, expressed in milliseconds, measured in lead III
x0ec104cP-Amplitude positive, III
Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead III
x0ec105cP-Amplitude negative, III
Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead III
x0ec106cPQ Time, III
Duration of PQ interval, expressed in milliseconds, measured in lead III
x0ec108cDuration Q wave, III
Duration of Q wave, expressed in milliseconds, measured in lead III
x0ec109cQ-Amplitude, III
Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead III
x0ec110cQRS Duration, III
Duration of QRS complex, expressed in milliseconds, measured in lead III
x0ec113cQT Time, III
Duration of QT interval, expressed in milliseconds, measured in lead III
x0ec115cDuration R wave, III
Duration of R wave, expressed in milliseconds, measured in lead III
x0ec120cR-Amplitude, III
Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead III
x0ec121cDuration R' wave, III
Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead III
x0ec122cR'-Amplitude, III
Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead III
x0ec123cDuration S wave, III
Duration of S wave, expressed in milliseconds, measured in lead III
x0ec125cS-Amplitude, III
Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead III
x0ec126cDuration S' wave, III
Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead III
x0ec127cS'-Amplitude, III
Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead III
x0ec128cST Value, III
ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead III
x0ec129cJ-ms, III
J point occurrence in the average beat computed over lead III, expressed in milliseconds
x0ec130cJ-Value, III
J point voltage value, expressed in milliVolts, measured in lead III
x0ec131cJT-Time, III
Duration of JT interval, expressed in milliseconds, measured in lead III
x0ec133cJTc-Time, III
Duration of JT interval corrected for the heart rate, expressed in milliseconds, measured in lead III
x0ec135cT-Amplitude, III
Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead III
x0ec137cPositive percentage of T-wave-area, III
Positive percentage of T-wave-area in lead III
x0ec138cNegative percentage of T-wave-area, III
Negative percentage of T-wave-area in lead III
x0ec139cDuration peak till end of T-Wave, III
Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead III
x0ec141cNoise, III
Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead III
x0ec143cQTc (Frid) Time, III
Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead III
x0ec152cQTc (Baz) Time, III
Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead III
x0ec153c