Measurments related to lead V1 in the 10s resting ECG

28 variables.

-

Duration P Wave, V1

Duration of P Wave, expressed in milliseconds, measured in lead V1

x0ec104g
P-Amplitude positive, V1

Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V1

x0ec105g
P-Amplitude negative, V1

Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V1

x0ec106g
PQ Time, V1

Duration of PQ interval, expressed in milliseconds, measured in lead V1

x0ec108g
Duration Q wave, V1

Duration of Q wave, expressed in milliseconds, measured in lead V1

x0ec109g
Q-Amplitude, V1

Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead V1

x0ec110g
QRS Duration, V1

Duration of QRS complex, expressed in milliseconds, measured in lead V1

x0ec113g
QT Time, V1

Duration of QT interval, expressed in milliseconds, measured in lead V1

x0ec115g
Duration R wave, V1

Duration of R wave, expressed in milliseconds, measured in lead V1

x0ec120g
R-Amplitude, V1

Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead V1

x0ec121g
Duration R' wave, V1

Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V1

x0ec122g
R'-Amplitude, V1

Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead V1

x0ec123g
Duration S wave, V1

Duration of S wave, expressed in milliseconds, measured in lead V1

x0ec125g
S-Amplitude, V1

Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead V1

x0ec126g
Duration S' wave, V1

Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V1

x0ec127g
S'-Amplitude, V1

Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead V1

x0ec128g
ST Value, V1

ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V1

x0ec129g
J-ms, V1

J point occurrence in the average beat computed over lead V1, expressed in milliseconds

x0ec130g
J-Value, V1

J point voltage value, expressed in milliVolts, measured in lead V1

x0ec131g
JT-Time, V1

Duration of JT interval, expressed in milliseconds, measured in lead V1

x0ec133g
JTc-Time, V1

Duration of JT interval corrected for the heart rate, expressed in milliseconds, measured in lead V1

x0ec135g
T-Amplitude, V1

Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead V1

x0ec137g
Positive percentage of T-wave-area, V1

Positive percentage of T-wave-area in lead V1

x0ec138g
Negative percentage of T-wave-area, V1

Negative percentage of T-wave-area in lead V1

x0ec139g
Duration peak till end of T-Wave, V1

Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V1

x0ec141g
Noise, V1

Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V1

x0ec143g
QTc (Frid) Time, V1

Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead V1

x0ec152g
QTc (Baz) Time, V1

Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead V1

x0ec153g