Measurments related to lead V2 in the 10s resting ECG

28 variables.

-

Duration P Wave, V2

Duration of P Wave, expressed in milliseconds, measured in lead V2

x0ec104h
P-Amplitude positive, V2

Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V2

x0ec105h
P-Amplitude negative, V2

Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V2

x0ec106h
PQ Time, V2

Duration of PQ interval, expressed in milliseconds, measured in lead V2

x0ec108h
Duration Q wave, V2

Duration of Q wave, expressed in milliseconds, measured in lead V2

x0ec109h
Q-Amplitude, V2

Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead V2

x0ec110h
QRS Duration, V2

Duration of QRS complex, expressed in milliseconds, measured in lead V2

x0ec113h
QT Time, V2

Duration of QT interval, expressed in milliseconds, measured in lead V2

x0ec115h
Duration R wave, V2

Duration of R wave, expressed in milliseconds, measured in lead V2

x0ec120h
R-Amplitude, V2

Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead V2

x0ec121h
Duration R' wave, V2

Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V2

x0ec122h
R'-Amplitude, V2

Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead V2

x0ec123h
Duration S wave, V2

Duration of S wave, expressed in milliseconds, measured in lead V2

x0ec125h
S-Amplitude, V2

Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead V2

x0ec126h
Duration S' wave, V2

Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V2

x0ec127h
S'-Amplitude, V2

Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead V2

x0ec128h
ST Value, V2

ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V2

x0ec129h
J-ms, V2

J point occurrence in the average beat computed over lead V2, expressed in milliseconds

x0ec130h
J-Value, V2

J point voltage value, expressed in milliVolts, measured in lead V2

x0ec131h
JT-Time, V2

Duration of JT interval, expressed in milliseconds, measured in lead V2

x0ec133h
JTc-Time, V2

Duration of JT interval corrected for the heart rate, expressed in milliseconds, measured in lead V2

x0ec135h
T-Amplitude, V2

Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead V2

x0ec137h
Positive percentage of T-wave-area, V2

Positive percentage of T-wave-area in lead V2

x0ec138h
Negative percentage of T-wave-area, V2

Negative percentage of T-wave-area in lead V2

x0ec139h
Duration peak till end of T-Wave, V2

Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V2

x0ec141h
Noise, V2

Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V2

x0ec143h
QTc (Frid) Time, V2

Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead V2

x0ec152h
QTc (Baz) Time, V2

Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead V2

x0ec153h