Measurments related to lead V3 in the 10s resting ECG
28 variables.
-
Duration P Wave, V3
Duration of P Wave, expressed in milliseconds, measured in lead V3
x0ec104iP-Amplitude positive, V3
Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V3
x0ec105iP-Amplitude negative, V3
Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V3
x0ec106iPQ Time, V3
Duration of PQ interval, expressed in milliseconds, measured in lead V3
x0ec108iDuration Q wave, V3
Duration of Q wave, expressed in milliseconds, measured in lead V3
x0ec109iQ-Amplitude, V3
Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead V3
x0ec110iQRS Duration, V3
Duration of QRS complex, expressed in milliseconds, measured in lead V3
x0ec113iQT Time, V3
Duration of QT interval, expressed in milliseconds, measured in lead V3
x0ec115iDuration R wave, V3
Duration of R wave, expressed in milliseconds, measured in lead V3
x0ec120iR-Amplitude, V3
Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead V3
x0ec121iDuration R' wave, V3
Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V3
x0ec122iR'-Amplitude, V3
Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead V3
x0ec123iDuration S wave, V3
Duration of S wave, expressed in milliseconds, measured in lead V3
x0ec125iS-Amplitude, V3
Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead V3
x0ec126iDuration S' wave, V3
Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V3
x0ec127iS'-Amplitude, V3
Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead V3
x0ec128iST Value, V3
ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V3
x0ec129iJ-ms, V3
J point occurrence in the average beat computed over lead V3, expressed in milliseconds
x0ec130iJ-Value, V3
J point voltage value, expressed in milliVolts, measured in lead V3
x0ec131iJT-Time, V3
Duration of JT interval, expressed in milliseconds, measured in lead V3
x0ec133iJTc-Time, V3
Duration of JT interval corrected for the heart rate, expressed in milliseconds, measured in lead V3
x0ec135iT-Amplitude, V3
Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead V3
x0ec137iPositive percentage of T-wave-area, V3
Positive percentage of T-wave-area in lead V3
x0ec138iNegative percentage of T-wave-area, V3
Negative percentage of T-wave-area in lead V3
x0ec139iDuration peak till end of T-Wave, V3
Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V3
x0ec141iNoise, V3
Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V3
x0ec143iQTc (Frid) Time, V3
Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead V3
x0ec152iQTc (Baz) Time, V3
Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead V3
x0ec153i