Measurments related to lead V4 in the 10s resting ECG
28 variables.
-
Duration P Wave, V4
Duration of P Wave, expressed in milliseconds, measured in lead V4
x0ec104jP-Amplitude positive, V4
Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V4
x0ec105jP-Amplitude negative, V4
Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V4
x0ec106jPQ Time, V4
Duration of PQ interval, expressed in milliseconds, measured in lead V4
x0ec108jDuration Q wave, V4
Duration of Q wave, expressed in milliseconds, measured in lead V4
x0ec109jQ-Amplitude, V4
Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead V4
x0ec110jQRS Duration, V4
Duration of QRS complex, expressed in milliseconds, measured in lead V4
x0ec113jQT Time, V4
Duration of QT interval, expressed in milliseconds, measured in lead V4
x0ec115jDuration R wave, V4
Duration of R wave, expressed in milliseconds, measured in lead V4
x0ec120jR-Amplitude, V4
Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead V4
x0ec121jDuration R' wave, V4
Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V4
x0ec122jR'-Amplitude, V4
Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead V4
x0ec123jDuration S wave, V4
Duration of S wave, expressed in milliseconds, measured in lead V4
x0ec125jS-Amplitude, V4
Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead V4
x0ec126jDuration S' wave, V4
Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V4
x0ec127jS'-Amplitude, V4
Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead V4
x0ec128jST Value, V4
ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V4
x0ec129jJ-ms, V4
J point occurrence in the average beat computed over lead V4, expressed in milliseconds
x0ec130jJ-Value, V4
J point voltage value, expressed in milliVolts, measured in lead V4
x0ec131jJT-Time, V4
Duration of JT interval, expressed in milliseconds, measured in lead V4
x0ec133jJTc-Time, V4
Duration of JT interval corrected for the heart rate, expressed in milliseconds, measured in lead V4
x0ec135jT-Amplitude, V4
Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead V4
x0ec137jPositive percentage of T-wave-area, V4
Positive percentage of T-wave-area in lead V4
x0ec138jNegative percentage of T-wave-area, V4
Negative percentage of T-wave-area in lead V4
x0ec139jDuration peak till end of T-Wave, V4
Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V4
x0ec141jNoise, V4
Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V4
x0ec143jQTc (Frid) Time, V4
Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead V4
x0ec152jQTc (Baz) Time, V4
Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead V4
x0ec153j