Measurments related to lead V4 in the 10s resting ECG

28 variables.

-

Duration P Wave, V4

Duration of P Wave, expressed in milliseconds, measured in lead V4

x0ec104j
P-Amplitude positive, V4

Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V4

x0ec105j
P-Amplitude negative, V4

Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V4

x0ec106j
PQ Time, V4

Duration of PQ interval, expressed in milliseconds, measured in lead V4

x0ec108j
Duration Q wave, V4

Duration of Q wave, expressed in milliseconds, measured in lead V4

x0ec109j
Q-Amplitude, V4

Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead V4

x0ec110j
QRS Duration, V4

Duration of QRS complex, expressed in milliseconds, measured in lead V4

x0ec113j
QT Time, V4

Duration of QT interval, expressed in milliseconds, measured in lead V4

x0ec115j
Duration R wave, V4

Duration of R wave, expressed in milliseconds, measured in lead V4

x0ec120j
R-Amplitude, V4

Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead V4

x0ec121j
Duration R' wave, V4

Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V4

x0ec122j
R'-Amplitude, V4

Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead V4

x0ec123j
Duration S wave, V4

Duration of S wave, expressed in milliseconds, measured in lead V4

x0ec125j
S-Amplitude, V4

Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead V4

x0ec126j
Duration S' wave, V4

Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V4

x0ec127j
S'-Amplitude, V4

Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead V4

x0ec128j
ST Value, V4

ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V4

x0ec129j
J-ms, V4

J point occurrence in the average beat computed over lead V4, expressed in milliseconds

x0ec130j
J-Value, V4

J point voltage value, expressed in milliVolts, measured in lead V4

x0ec131j
JT-Time, V4

Duration of JT interval, expressed in milliseconds, measured in lead V4

x0ec133j
JTc-Time, V4

Duration of JT interval corrected for the heart rate, expressed in milliseconds, measured in lead V4

x0ec135j
T-Amplitude, V4

Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead V4

x0ec137j
Positive percentage of T-wave-area, V4

Positive percentage of T-wave-area in lead V4

x0ec138j
Negative percentage of T-wave-area, V4

Negative percentage of T-wave-area in lead V4

x0ec139j
Duration peak till end of T-Wave, V4

Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V4

x0ec141j
Noise, V4

Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V4

x0ec143j
QTc (Frid) Time, V4

Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead V4

x0ec152j
QTc (Baz) Time, V4

Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead V4

x0ec153j