Measurments related to lead aVL in the 10s resting ECG
28 variables.
-
Duration P Wave, aVL
Duration of P Wave, expressed in milliseconds, measured in lead aVL
x0ec104eP-Amplitude positive, aVL
Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead aVL
x0ec105eP-Amplitude negative, aVL
Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead aVL
x0ec106ePQ Time, aVL
Duration of PQ interval, expressed in milliseconds, measured in lead aVL
x0ec108eDuration Q wave, aVL
Duration of Q wave, expressed in milliseconds, measured in lead aVL
x0ec109eQ-Amplitude, aVL
Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead aVL
x0ec110eQRS Duration, aVL
Duration of QRS complex, expressed in milliseconds, measured in lead aVL
x0ec113eQT Time, aVL
Duration of QT interval, expressed in milliseconds, measured in lead aVL
x0ec115eDuration R wave, aVL
Duration of R wave, expressed in milliseconds, measured in lead aVL
x0ec120eR-Amplitude, aVL
Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead aVL
x0ec121eDuration R' wave, aVL
Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVL
x0ec122eR'-Amplitude, aVL
Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead aVL
x0ec123eDuration S wave, aVL
Duration of S wave, expressed in milliseconds, measured in lead aVL
x0ec125eS-Amplitude, aVL
Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead aVL
x0ec126eDuration S' wave, aVL
Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVL
x0ec127eS'-Amplitude, aVL
Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead aVL
x0ec128eST Value, aVL
ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead aVL
x0ec129eJ-ms, aVL
J point occurrence in the average beat computed over lead aVL, expressed in milliseconds
x0ec130eJ-Value, aVL
J point voltage value, expressed in milliVolts, measured in lead aVL
x0ec131eJT-Time, aVL
Duration of JT interval, expressed in milliseconds, measured in lead aVL
x0ec133eJTc-Time, aVL
Duration of JT interval corrected for the heart rate, expressed in milliseconds, measured in lead aVL
x0ec135eT-Amplitude, aVL
Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead aVL
x0ec137ePositive percentage of T-wave-area, aVL
Positive percentage of T-wave-area in lead aVL
x0ec138eNegative percentage of T-wave-area, aVL
Negative percentage of T-wave-area in lead aVL
x0ec139eDuration peak till end of T-Wave, aVL
Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead aVL
x0ec141eNoise, aVL
Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVL
x0ec143eQTc (Frid) Time, aVL
Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead aVL
x0ec152eQTc (Baz) Time, aVL
Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead aVL
x0ec153e