Measurments related to lead aVL in the 10s resting ECG

28 variables.

-

Duration P Wave, aVL

Duration of P Wave, expressed in milliseconds, measured in lead aVL

x0ec104e
P-Amplitude positive, aVL

Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead aVL

x0ec105e
P-Amplitude negative, aVL

Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead aVL

x0ec106e
PQ Time, aVL

Duration of PQ interval, expressed in milliseconds, measured in lead aVL

x0ec108e
Duration Q wave, aVL

Duration of Q wave, expressed in milliseconds, measured in lead aVL

x0ec109e
Q-Amplitude, aVL

Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead aVL

x0ec110e
QRS Duration, aVL

Duration of QRS complex, expressed in milliseconds, measured in lead aVL

x0ec113e
QT Time, aVL

Duration of QT interval, expressed in milliseconds, measured in lead aVL

x0ec115e
Duration R wave, aVL

Duration of R wave, expressed in milliseconds, measured in lead aVL

x0ec120e
R-Amplitude, aVL

Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead aVL

x0ec121e
Duration R' wave, aVL

Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVL

x0ec122e
R'-Amplitude, aVL

Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead aVL

x0ec123e
Duration S wave, aVL

Duration of S wave, expressed in milliseconds, measured in lead aVL

x0ec125e
S-Amplitude, aVL

Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead aVL

x0ec126e
Duration S' wave, aVL

Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVL

x0ec127e
S'-Amplitude, aVL

Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead aVL

x0ec128e
ST Value, aVL

ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead aVL

x0ec129e
J-ms, aVL

J point occurrence in the average beat computed over lead aVL, expressed in milliseconds

x0ec130e
J-Value, aVL

J point voltage value, expressed in milliVolts, measured in lead aVL

x0ec131e
JT-Time, aVL

Duration of JT interval, expressed in milliseconds, measured in lead aVL

x0ec133e
JTc-Time, aVL

Duration of JT interval corrected for the heart rate, expressed in milliseconds, measured in lead aVL

x0ec135e
T-Amplitude, aVL

Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead aVL

x0ec137e
Positive percentage of T-wave-area, aVL

Positive percentage of T-wave-area in lead aVL

x0ec138e
Negative percentage of T-wave-area, aVL

Negative percentage of T-wave-area in lead aVL

x0ec139e
Duration peak till end of T-Wave, aVL

Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead aVL

x0ec141e
Noise, aVL

Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVL

x0ec143e
QTc (Frid) Time, aVL

Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead aVL

x0ec152e
QTc (Baz) Time, aVL

Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead aVL

x0ec153e