Measurments related to lead aVR in the 10s resting ECG
28 variables.
-
Duration P Wave, aVR
Duration of P Wave, expressed in milliseconds, measured in lead aVR
x0ec104dP-Amplitude positive, aVR
Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead aVR
x0ec105dP-Amplitude negative, aVR
Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead aVR
x0ec106dPQ Time, aVR
Duration of PQ interval, expressed in milliseconds, measured in lead aVR
x0ec108dDuration Q wave, aVR
Duration of Q wave, expressed in milliseconds, measured in lead aVR
x0ec109dQ-Amplitude, aVR
Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead aVR
x0ec110dQRS Duration, aVR
Duration of QRS complex, expressed in milliseconds, measured in lead aVR
x0ec113dQT Time, aVR
Duration of QT interval, expressed in milliseconds, measured in lead aVR
x0ec115dDuration R wave, aVR
Duration of R wave, expressed in milliseconds, measured in lead aVR
x0ec120dR-Amplitude, aVR
Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead aVR
x0ec121dDuration R' wave, aVR
Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVR
x0ec122dR'-Amplitude, aVR
Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead aVR
x0ec123dDuration S wave, aVR
Duration of S wave, expressed in milliseconds, measured in lead aVR
x0ec125dS-Amplitude, aVR
Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead aVR
x0ec126dDuration S' wave, aVR
Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVR
x0ec127dS'-Amplitude, aVR
Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead aVR
x0ec128dST Value, aVR
ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead aVR
x0ec129dJ-ms, aVR
J point occurrence in the average beat computed over lead aVR, expressed in milliseconds
x0ec130dJ-Value, aVR
J point voltage value, expressed in milliVolts, measured in lead aVR
x0ec131dJT-Time, aVR
Duration of JT interval, expressed in milliseconds, measured in lead aVR
x0ec133dJTc-Time, aVR
Duration of JT interval corrected for the heart rate, expressed in milliseconds, measured in lead aVR
x0ec135dT-Amplitude, aVR
Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead aVR
x0ec137dPositive percentage of T-wave-area, aVR
Positive percentage of T-wave-area in lead aVR
x0ec138dNegative percentage of T-wave-area, aVR
Negative percentage of T-wave-area in lead aVR
x0ec139dDuration peak till end of T-Wave, aVR
Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead aVR
x0ec141dNoise, aVR
Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVR
x0ec143dQTc (Frid) Time, aVR
Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead aVR
x0ec152dQTc (Baz) Time, aVR
Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead aVR
x0ec153d