Variables

505 variables.
Clear
Module Label Name Description Type
ECG 10s (CHRIS baseline) x0ec102 Axis P Wave Average direction of the heart vector during electrical depolarization of the atria, expressed in degree Integer
ECG 10s (CHRIS baseline) x0ec111 Axis QRS Average direction of the heart vector during electrical depolarization of the ventricles, expressed in degree Integer
ECG 10s (CHRIS baseline) x0ec136 Axis T Wave Average direction of the heart vector during electrical repolarization of the ventricles, expressed in degree Integer
ECG 10s (CHRIS baseline) x0ec140 Dispersion peak till end of T-Wave It is defined as the difference between the longest and the shortest peak-to-end of the T wave measured in the 12 ECG leads, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec104 Duration P Wave Duration of P Wave, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec104a Duration P Wave, I Duration of P Wave, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec104b Duration P Wave, II Duration of P Wave, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec104c Duration P Wave, III Duration of P Wave, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec104g Duration P Wave, V1 Duration of P Wave, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec104h Duration P Wave, V2 Duration of P Wave, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec104i Duration P Wave, V3 Duration of P Wave, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec104j Duration P Wave, V4 Duration of P Wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec104k Duration P Wave, V5 Duration of P Wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec104l Duration P Wave, V6 Duration of P Wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec104f Duration P Wave, aVF Duration of P Wave, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec104e Duration P Wave, aVL Duration of P Wave, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec104d Duration P Wave, aVR Duration of P Wave, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec109a Duration Q wave, I Duration of Q wave, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec109b Duration Q wave, II Duration of Q wave, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec109c Duration Q wave, III Duration of Q wave, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec109g Duration Q wave, V1 Duration of Q wave, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec109h Duration Q wave, V2 Duration of Q wave, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec109i Duration Q wave, V3 Duration of Q wave, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec109j Duration Q wave, V4 Duration of Q wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec109k Duration Q wave, V5 Duration of Q wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec109l Duration Q wave, V6 Duration of Q wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec109f Duration Q wave, aVF Duration of Q wave, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec109e Duration Q wave, aVL Duration of Q wave, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec109d Duration Q wave, aVR Duration of Q wave, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec120a Duration R wave, I Duration of R wave, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec120b Duration R wave, II Duration of R wave, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec120c Duration R wave, III Duration of R wave, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec120g Duration R wave, V1 Duration of R wave, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec120h Duration R wave, V2 Duration of R wave, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec120i Duration R wave, V3 Duration of R wave, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec120j Duration R wave, V4 Duration of R wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec120k Duration R wave, V5 Duration of R wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec120l Duration R wave, V6 Duration of R wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec120f Duration R wave, aVF Duration of R wave, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec120e Duration R wave, aVL Duration of R wave, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec120d Duration R wave, aVR Duration of R wave, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec122a Duration R' wave, I Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec122b Duration R' wave, II Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec122c Duration R' wave, III Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec122g Duration R' wave, V1 Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec122h Duration R' wave, V2 Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec122i Duration R' wave, V3 Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec122j Duration R' wave, V4 Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec122k Duration R' wave, V5 Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec122l Duration R' wave, V6 Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec122f Duration R' wave, aVF Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec122e Duration R' wave, aVL Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec122d Duration R' wave, aVR Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec125a Duration S wave, I Duration of S wave, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec125b Duration S wave, II Duration of S wave, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec125c Duration S wave, III Duration of S wave, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec125g Duration S wave, V1 Duration of S wave, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec125h Duration S wave, V2 Duration of S wave, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec125i Duration S wave, V3 Duration of S wave, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec125j Duration S wave, V4 Duration of S wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec125k Duration S wave, V5 Duration of S wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec125l Duration S wave, V6 Duration of S wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec125f Duration S wave, aVF Duration of S wave, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec125e Duration S wave, aVL Duration of S wave, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec125d Duration S wave, aVR Duration of S wave, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec127a Duration S' wave, I Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec127b Duration S' wave, II Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec127c Duration S' wave, III Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec127g Duration S' wave, V1 Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec127h Duration S' wave, V2 Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec127i Duration S' wave, V3 Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec127j Duration S' wave, V4 Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec127k Duration S' wave, V5 Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec127l Duration S' wave, V6 Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec127f Duration S' wave, aVF Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec127e Duration S' wave, aVL Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec127d Duration S' wave, aVR Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec141a Duration peak till end of T-Wave, I Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec141b Duration peak till end of T-Wave, II Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec141c Duration peak till end of T-Wave, III Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec141g Duration peak till end of T-Wave, V1 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec141h Duration peak till end of T-Wave, V2 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec141i Duration peak till end of T-Wave, V3 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec141j Duration peak till end of T-Wave, V4 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec141k Duration peak till end of T-Wave, V5 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec141l Duration peak till end of T-Wave, V6 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec141f Duration peak till end of T-Wave, aVF Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec141e Duration peak till end of T-Wave, aVL Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec141d Duration peak till end of T-Wave, aVR Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec101 Heart Rate, Resting Heart Rate at rest, expressed in beat-per-minute Integer
ECG 10s (CHRIS baseline) x0ec146 Heart rate as RR Heart rate expressed as RR interval, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec130 J-ms J point occurrence in the average beat, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec130a J-ms, I J point occurrence in the average beat computed over lead I, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec130b J-ms, II J point occurrence in the average beat computed over lead II, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec130c J-ms, III J point occurrence in the average beat computed over lead III, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec130g J-ms, V1 J point occurrence in the average beat computed over lead V1, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec130h J-ms, V2 J point occurrence in the average beat computed over lead V2, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec130i J-ms, V3 J point occurrence in the average beat computed over lead V3, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec130j J-ms, V4 J point occurrence in the average beat computed over lead V4, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec130k J-ms, V5 J point occurrence in the average beat computed over lead V5, expressed in milliseconds Integer