Variables

505 variables.
Clear
Module Label Name Description Type
ECG 10s (CHRIS baseline) x0ec139f Negative percentage of T-wave-area, aVF Negative percentage of T-wave-area in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec139g Negative percentage of T-wave-area, V1 Negative percentage of T-wave-area in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec139h Negative percentage of T-wave-area, V2 Negative percentage of T-wave-area in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec139i Negative percentage of T-wave-area, V3 Negative percentage of T-wave-area in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec139j Negative percentage of T-wave-area, V4 Negative percentage of T-wave-area in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec139k Negative percentage of T-wave-area, V5 Negative percentage of T-wave-area in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec139l Negative percentage of T-wave-area, V6 Negative percentage of T-wave-area in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec140 Dispersion peak till end of T-Wave It is defined as the difference between the longest and the shortest peak-to-end of the T wave measured in the 12 ECG leads, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec141a Duration peak till end of T-Wave, I Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec141b Duration peak till end of T-Wave, II Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec141c Duration peak till end of T-Wave, III Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec141d Duration peak till end of T-Wave, aVR Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec141e Duration peak till end of T-Wave, aVL Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec141f Duration peak till end of T-Wave, aVF Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec141g Duration peak till end of T-Wave, V1 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec141h Duration peak till end of T-Wave, V2 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec141i Duration peak till end of T-Wave, V3 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec141j Duration peak till end of T-Wave, V4 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec141k Duration peak till end of T-Wave, V5 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec141l Duration peak till end of T-Wave, V6 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec142 Sokolow-Index Sokolow-Index index for left ventricular hypertrophy, calculated as the sum of the amplitudes of the S wave in V1 and the R wave in V5 or V6 (whichever is larger), expressed in milliVolts [https://doi.org/10.1016/0002-8703(49)90562-1] Float
ECG 10s (CHRIS baseline) x0ec143a Noise, I Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec143b Noise, II Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec143c Noise, III Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec143d Noise, aVR Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec143e Noise, aVL Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec143f Noise, aVF Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec143g Noise, V1 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec143h Noise, V2 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec143i Noise, V3 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec143j Noise, V4 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec143k Noise, V5 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec143l Noise, V6 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec145 Heart axis type Heart axis type Categorical
ECG 10s (CHRIS baseline) x0ec146 Heart rate as RR Heart rate expressed as RR interval, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec148 Original Customed Version Original version of Custo Software at the time of the ECG exam acquisition Categorical
ECG 10s (CHRIS baseline) x0ec149 Automatic diagnosis by the software Automatic diagnosis with main findings, given by the software Character
ECG 10s (CHRIS baseline) x0ec150 Automatic diagnosis in English Automatic diagnosis with main findings, given by the software, translated into English Character
ECG 10s (CHRIS baseline) x0ec150a1 Bradycardic rhythm Token «bradycardic rhythm» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150a2 Bradycardic sinus rhythm Token «bradycardic sinus rhythm» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150a3 Bradycardic sinus rhythm with sinus arrhythmia Token «bradycardic sinus rhythm with sinus arrhythmia» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150a4 Normofrequency sinus rhythm Token «normofrequency sinus rhythm» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150a5 Normofrequency sinus rhythm with sinus arrhythmia Token «normofrequency sinus rhythm with sinus arrhythmia» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150a6 Tachycardiac sinus rhythm Token «tachycardiac sinus rhythm» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150a7 Tachycardiac sinus rhythm with sinus arrhythmia Token «tachycardiac sinus rhythm with sinus arrhythmia» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150aa1 Negative T wave in channel I Token «negative T wave in channel I» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150aa10 Negative T wave in channel V6 Token «negative T wave in channel V6» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150aa2 Negative T wave in channel II Token «negative T wave in channel II» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150aa3 Negative T wave in channel III Token «negative T wave in channel III» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150aa4 Negative T wave in channel aVL Token «negative T wave in channel aVL» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150aa5 Negative T wave in channel aVF Token «negative T wave in channel aVF» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150aa6 Negative T wave in channel V2 Token «negative T wave in channel V2» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150aa7 Negative T wave in channel V3 Token «negative T wave in channel V3» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150aa8 Negative T wave in channel V4 Token «negative T wave in channel V4» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150aa9 Negative T wave in channel V5 Token «negative T wave in channel V5» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab1 No further interpretation was possible, since no sum complex could be created Token «No further interpretation was possible, since no sum complex could be created» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab10 Note: Channel 'aVF' cannot be measured Token «Note: Channel 'aVF' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab11 Note: Channel 'aVL' cannot be measured Token «Note: Channel 'aVL' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab2 Note: Channel 'I' cannot be measured Token «Note: Channel 'I' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab3 Note: Channel 'II' cannot be measured Token «Note: Channel 'II' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab4 Note: Channel 'III' cannot be measured Token «Note: Channel 'III' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab5 Note: Channel 'V1' cannot be measured Token «Note: Channel 'V1' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab6 Note: Channel 'V2' cannot be measured Token «Note: Channel 'V2' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab7 Note: Channel 'V3' cannot be measured Token «Note: Channel 'V3' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab8 Note: Channel 'V4' cannot be measured Token «Note: Channel 'V4' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab9 Note: Channel 'V5' cannot be measured Token «Note: Channel 'V5' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ac1 Normal EKG Token «normal EKG» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ac2 Otherwise normal EKG Token «otherwise normal EKG» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150b1 Atrial fibrillation with bradycardic conduction Token «Atrial fibrillation with bradycardic conduction» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150b2 Atrial fibrillation with normofrequency conduction Token «Atrial fibrillation with normofrequency conduction» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150b3 Atrial fibrillation with tachycardiac conduction Token «Atrial fibrillation with tachycardiac conduction» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150b4 Atrial fibrillation with variable conduction Token «Atrial fibrillation with variable conduction» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150c1 Normal type Token «Normal type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150c2 Left type Token «Left type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150c3 Right type Token «Right type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150c4 Sagittal type Token «Sagittal type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150c5 Steep type Token «Steep type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150c6 Overturned left type Token «overturned left type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150c7 Overturned right type Token «overturned right type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150d1 1 VES Token «1 VES» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150d2 3 monotopic VES Token «3 monotopic VES» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150d3 4 monotopic VES Token «4 monotopic VES» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150d4 2 polytopic VES Token «2 polytopic VES» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150d5 4 polytopic VES Token «4 polytopic VES» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150e1 1 SVES Token «1 SVES» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150e2 2 SVES Token «2 SVES» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150e3 3 SVES Token «3 SVES» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150e4 4 SVES Token «4 SVES» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150f1 1st degree AV block Token «1st degree AV block» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150g1 2 monotopic PVCs Token «2 monotopic PVCs» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150h1 3 ventricular couplets Token «3 ventricular couplets» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150i1 2nd degree AV block Token «2nd degree AV block» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150i2 Mobitz type Token «Mobitz type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150i3 Wenckebach type Token «Wenckebach type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150j1 Right bundle branch block Token «Right bundle branch block» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150j2 Incomplete right bundle branch block Token «incomplete right bundle branch block» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150k1 Left bundle branch block Token «Left bundle branch block» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150k2 Left bundle branch block possible Token «Left bundle branch block possible» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150l1 Left anterior hemiblock Token «left anterior hemiblock» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150m1 Left ventricular hypertrophy Token «left ventricular hypertrophy» is present in automated diagnosis Boolean