Variables

505 variables.
Clear
Module Label Name Description Type
ECG 10s (CHRIS baseline) x0ec126f S-Amplitude, aVF Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec126g S-Amplitude, V1 Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec126h S-Amplitude, V2 Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec126i S-Amplitude, V3 Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec126j S-Amplitude, V4 Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec126k S-Amplitude, V5 Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec126l S-Amplitude, V6 Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec128a S'-Amplitude, I Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec128b S'-Amplitude, II Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec128c S'-Amplitude, III Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec128d S'-Amplitude, aVR Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec128e S'-Amplitude, aVL Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec128f S'-Amplitude, aVF Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec128g S'-Amplitude, V1 Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec128h S'-Amplitude, V2 Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec128j S'-Amplitude, V4 Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec128k S'-Amplitude, V5 Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec128l S'-Amplitude, V6 Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec129a ST Value, I ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec129b ST Value, II ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec129c ST Value, III ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec129d ST Value, aVR ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec131g J-Value, V1 J point voltage value, expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec129g ST Value, V1 ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec129h ST Value, V2 ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec129i ST Value, V3 ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec142 Sokolow-Index Sokolow-Index index for left ventricular hypertrophy, calculated as the sum of the amplitudes of the S wave in V1 and the R wave in V5 or V6 (whichever is larger), expressed in milliVolts [https://doi.org/10.1016/0002-8703(49)90562-1] Float
ECG 10s (CHRIS baseline) x0ec129l ST Value, V6 ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec131a J-Value, I J point voltage value, expressed in milliVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec131b J-Value, II J point voltage value, expressed in milliVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec131c J-Value, III J point voltage value, expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec131d J-Value, aVR J point voltage value, expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec131e J-Value, aVL J point voltage value, expressed in milliVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec131f J-Value, aVF J point voltage value, expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec131i J-Value, V3 J point voltage value, expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec131j J-Value, V4 J point voltage value, expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec131k J-Value, V5 J point voltage value, expressed in milliVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec131l J-Value, V6 J point voltage value, expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec137a T-Amplitude, I Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec137b T-Amplitude, II Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec137c T-Amplitude, III Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec137d T-Amplitude, aVR Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec137e T-Amplitude, aVL Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec137f T-Amplitude, aVF Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec137g T-Amplitude, V1 Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec137h T-Amplitude, V2 Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec137i T-Amplitude, V3 Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec137j T-Amplitude, V4 Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec137k T-Amplitude, V5 Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec137l T-Amplitude, V6 Voltage amplitude of the peak of T wave, expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec143a Noise, I Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec143d Noise, aVR Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec143e Noise, aVL Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec143f Noise, aVF Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec143g Noise, V1 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec143h Noise, V2 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec143i Noise, V3 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec143j Noise, V4 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec143k Noise, V5 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec143l Noise, V6 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec154a QTc (Frid), percent of the target QTc, calculated with Fridericia formula, expressed as percentange of the target value of 390ms Float
ECG 10s (CHRIS baseline) x0ec154b QTc (Baz), percent of the target QTc, calculated with Bazett formula, expressed as percentange of the target value of 390ms Float
ECG 10s (CHRIS baseline) x0ec105h P-Amplitude positive, V2 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec106j P-Amplitude negative, V4 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec110b Q-Amplitude, II Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec110c Q-Amplitude, III Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec121i R-Amplitude, V3 Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec123h R'-Amplitude, V2 Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec123l R'-Amplitude, V6 Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec126d S-Amplitude, aVR Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec128i S'-Amplitude, V3 Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec129j ST Value, V4 ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec131h J-Value, V2 J point voltage value, expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec143b Noise, II Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec143c Noise, III Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec105a P-Amplitude positive, I Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec129e ST Value, aVL ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec129f ST Value, aVF ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec141g Duration peak till end of T-Wave, V1 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec141h Duration peak till end of T-Wave, V2 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec141i Duration peak till end of T-Wave, V3 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec141j Duration peak till end of T-Wave, V4 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec141k Duration peak till end of T-Wave, V5 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec141l Duration peak till end of T-Wave, V6 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec101 Heart Rate, Resting Heart Rate at rest, expressed in beat-per-minute Integer
ECG 10s (CHRIS baseline) x0ec135k JTc-Time, V5 Duration of JT interval corrected for the heart rate, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec135 JTc-Time Duration of JT interval corrected for the heart rate (by definition: JTc = QTc - QRS), expressed in milliseconds. By definition, JTc is a more specific measurement of ventricular repolarization than the QTc by eliminating QRS duration variability, and a more sensitive predictor for repolarization abnormalities Integer
ECG 10s (CHRIS baseline) x0ec108a PQ Time, I Duration of PQ interval, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec108 PQ Time Duration of PQ interval (from the beginning of the P wave to the beginning of the QRS complex), expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec107 PQ-Dispersion PQ interval dispersion is defined as the difference between the longest and the shortest PQ interval duration measured in the 12 ECG leads, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec104l Duration P Wave, V6 Duration of P Wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec104k Duration P Wave, V5 Duration of P Wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec104j Duration P Wave, V4 Duration of P Wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec104i Duration P Wave, V3 Duration of P Wave, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec104g Duration P Wave, V1 Duration of P Wave, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec135j JTc-Time, V4 Duration of JT interval corrected for the heart rate, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec146 Heart rate as RR Heart rate expressed as RR interval, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec135i JTc-Time, V3 Duration of JT interval corrected for the heart rate, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec135g JTc-Time, V1 Duration of JT interval corrected for the heart rate, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec135f JTc-Time, aVF Duration of JT interval corrected for the heart rate, expressed in milliseconds, measured in lead aVF Integer