Variables

4291 variables.
Clear
Module Label Name Description Type
ECG 10s (CHRIS baseline) x0ec141k Duration peak till end of T-Wave, V5 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec141j Duration peak till end of T-Wave, V4 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec141i Duration peak till end of T-Wave, V3 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec141h Duration peak till end of T-Wave, V2 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec141g Duration peak till end of T-Wave, V1 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec141c Duration peak till end of T-Wave, III Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec141b Duration peak till end of T-Wave, II Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec141a Duration peak till end of T-Wave, I Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec142 Sokolow-Index Sokolow-Index index for left ventricular hypertrophy, calculated as the sum of the amplitudes of the S wave in V1 and the R wave in V5 or V6 (whichever is larger), expressed in milliVolts [https://doi.org/10.1016/0002-8703(49)90562-1] Float
ECG 10s (CHRIS baseline) x0ec129d ST Value, aVR ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec129e ST Value, aVL ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec129f ST Value, aVF ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec129l ST Value, V6 ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec129k ST Value, V5 ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec129j ST Value, V4 ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec129i ST Value, V3 ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec129h ST Value, V2 ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec129g ST Value, V1 ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec129c ST Value, III ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec129b ST Value, II ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec129a ST Value, I ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec154a QTc (Frid), percent of the target QTc, calculated with Fridericia formula, expressed as percentange of the target value of 390ms Float
ECG 10s (CHRIS baseline) x0ec154b QTc (Baz), percent of the target QTc, calculated with Bazett formula, expressed as percentange of the target value of 390ms Float
ECG 10s (CHRIS baseline) x0ec151b QTc (Baz) Dispersion QTc interval dispersion is defined as the difference between the longest and the shortest QT interval duration (with Bazett formula) measured in the 12 ECG leads, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec151a QTc (Frid) Dispersion QTc dispersion is defined as the difference between the longest and the shortest QTc duration (with Fridericia formula) measured in the 12 ECG leads, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec114 QT-Dispersion QT interval dispersion is defined as the difference between the longest and the shortest QT interval duration measured in the 12 ECG leads, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec112 QRS-Dispersion QRS dispersion is defined as the difference between the longest and the shortest QRS complex measured in the 12 ECG leads, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec138d Positive percentage of T-wave-area, aVR Positive percentage of T-wave-area in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec138e Positive percentage of T-wave-area, aVL Positive percentage of T-wave-area in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec138f Positive percentage of T-wave-area, aVF Positive percentage of T-wave-area in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec138l Positive percentage of T-wave-area, V6 Positive percentage of T-wave-area in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec138k Positive percentage of T-wave-area, V5 Positive percentage of T-wave-area in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec138j Positive percentage of T-wave-area, V4 Positive percentage of T-wave-area in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec138i Positive percentage of T-wave-area, V3 Positive percentage of T-wave-area in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec138h Positive percentage of T-wave-area, V2 Positive percentage of T-wave-area in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec138g Positive percentage of T-wave-area, V1 Positive percentage of T-wave-area in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec138c Positive percentage of T-wave-area, III Positive percentage of T-wave-area in lead III Integer
ECG 10s (CHRIS baseline) x0ec138b Positive percentage of T-wave-area, II Positive percentage of T-wave-area in lead II Integer
ECG 10s (CHRIS baseline) x0ec138a Positive percentage of T-wave-area, I Positive percentage of T-wave-area in lead I Integer
ECG 10s (CHRIS baseline) x0ec105d P-Amplitude positive, aVR Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec105e P-Amplitude positive, aVL Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec105f P-Amplitude positive, aVF Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec105l P-Amplitude positive, V6 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec105k P-Amplitude positive, V5 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec105j P-Amplitude positive, V4 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec105i P-Amplitude positive, V3 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec105h P-Amplitude positive, V2 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec105g P-Amplitude positive, V1 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec105c P-Amplitude positive, III Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec105b P-Amplitude positive, II Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec105a P-Amplitude positive, I Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec106d P-Amplitude negative, aVR Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec106e P-Amplitude negative, aVL Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec106f P-Amplitude negative, aVF Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec106l P-Amplitude negative, V6 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec106k P-Amplitude negative, V5 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec106j P-Amplitude negative, V4 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec106i P-Amplitude negative, V3 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec106h P-Amplitude negative, V2 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec106g P-Amplitude negative, V1 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec106c P-Amplitude negative, III Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec106b P-Amplitude negative, II Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec106a P-Amplitude negative, I Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec107 PQ-Dispersion PQ interval dispersion is defined as the difference between the longest and the shortest PQ interval duration measured in the 12 ECG leads, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec103 P-Dispersion P wave dispersion is defined as the difference between the longest and the shortest P wave duration measured in the 12 ECG leads, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec148 Original Customed Version Original version of Custo Software at the time of the ECG exam acquisition Categorical
ECG 10s (CHRIS baseline) x0ec143d Noise, aVR Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec143e Noise, aVL Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec143f Noise, aVF Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec143l Noise, V6 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec143k Noise, V5 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec143j Noise, V4 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec143i Noise, V3 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec143h Noise, V2 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec143g Noise, V1 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec143c Noise, III Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec143b Noise, II Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec143a Noise, I Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec139d Negative percentage of T-wave-area, aVR Negative percentage of T-wave-area in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec139e Negative percentage of T-wave-area, aVL Negative percentage of T-wave-area in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec139f Negative percentage of T-wave-area, aVF Negative percentage of T-wave-area in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec139l Negative percentage of T-wave-area, V6 Negative percentage of T-wave-area in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec139k Negative percentage of T-wave-area, V5 Negative percentage of T-wave-area in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec139j Negative percentage of T-wave-area, V4 Negative percentage of T-wave-area in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec139i Negative percentage of T-wave-area, V3 Negative percentage of T-wave-area in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec139h Negative percentage of T-wave-area, V2 Negative percentage of T-wave-area in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec139g Negative percentage of T-wave-area, V1 Negative percentage of T-wave-area in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec139c Negative percentage of T-wave-area, III Negative percentage of T-wave-area in lead III Integer
ECG 10s (CHRIS baseline) x0ec139b Negative percentage of T-wave-area, II Negative percentage of T-wave-area in lead II Integer
ECG 10s (CHRIS baseline) x0ec139a Negative percentage of T-wave-area, I Negative percentage of T-wave-area in lead I Integer
ECG 10s (CHRIS baseline) x0ec124b Median of RR-Intervals Median of RR-Intervals (computed over the customed beat series), expressed in milliseconds Float
ECG 10s (CHRIS baseline) x0ec124a Mean of RR-Intervals Mean of RR-Intervals (computed over the customed beat series), expressed in milliseconds Float
ECG 10s (CHRIS baseline) x0ec134 JTc-Dispersion JTc dispersion is defined as the difference between the longest and the shortest JTc duration measured in the 12 ECG leads, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec132 JT-Dispersion JT interval dispersion is defined as the difference between the longest and the shortest JT interval duration measured in the 12 ECG leads, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec131d J-Value, aVR J point voltage value, expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec131e J-Value, aVL J point voltage value, expressed in milliVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec131f J-Value, aVF J point voltage value, expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec131l J-Value, V6 J point voltage value, expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec131k J-Value, V5 J point voltage value, expressed in milliVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec131j J-Value, V4 J point voltage value, expressed in milliVolts, measured in lead V4 Float