Variables

4291 variables.
Clear
Module Label Name Description Type
ECG 10s (CHRIS baseline) x0ec150z25 Possible inferior infarction Token «possible inferior infarction» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150z24 Possible anteroseptal infarction Token «possible anteroseptal infarction» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150z23 Possible acute anteroseptal infarction Token «possible acute anteroseptal infarction» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec138d Positive percentage of T-wave-area, aVR Positive percentage of T-wave-area in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec138e Positive percentage of T-wave-area, aVL Positive percentage of T-wave-area in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec138f Positive percentage of T-wave-area, aVF Positive percentage of T-wave-area in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec138l Positive percentage of T-wave-area, V6 Positive percentage of T-wave-area in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec138k Positive percentage of T-wave-area, V5 Positive percentage of T-wave-area in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec138j Positive percentage of T-wave-area, V4 Positive percentage of T-wave-area in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec138i Positive percentage of T-wave-area, V3 Positive percentage of T-wave-area in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec138h Positive percentage of T-wave-area, V2 Positive percentage of T-wave-area in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec138g Positive percentage of T-wave-area, V1 Positive percentage of T-wave-area in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec138c Positive percentage of T-wave-area, III Positive percentage of T-wave-area in lead III Integer
ECG 10s (CHRIS baseline) x0ec138b Positive percentage of T-wave-area, II Positive percentage of T-wave-area in lead II Integer
ECG 10s (CHRIS baseline) x0ec138a Positive percentage of T-wave-area, I Positive percentage of T-wave-area in lead I Integer
ECG 10s (CHRIS baseline) x0ec150v1 Peripheral low voltage Token «peripheral low voltage» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150w1 Pacemaker EKG Token «Pacemaker EKG» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec107 PQ-Dispersion PQ interval dispersion is defined as the difference between the longest and the shortest PQ interval duration measured in the 12 ECG leads, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec108d PQ Time, aVR Duration of PQ interval, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec108e PQ Time, aVL Duration of PQ interval, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec108f PQ Time, aVF Duration of PQ interval, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec108l PQ Time, V6 Duration of PQ interval, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec108k PQ Time, V5 Duration of PQ interval, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec108j PQ Time, V4 Duration of PQ interval, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec108i PQ Time, V3 Duration of PQ interval, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec108h PQ Time, V2 Duration of PQ interval, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec108g PQ Time, V1 Duration of PQ interval, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec108c PQ Time, III Duration of PQ interval, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec108b PQ Time, II Duration of PQ interval, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec108a PQ Time, I Duration of PQ interval, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec108 PQ Time Duration of PQ interval (from the beginning of the P wave to the beginning of the QRS complex), expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec103 P-Dispersion P wave dispersion is defined as the difference between the longest and the shortest P wave duration measured in the 12 ECG leads, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec105d P-Amplitude positive, aVR Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec105e P-Amplitude positive, aVL Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec105f P-Amplitude positive, aVF Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec105l P-Amplitude positive, V6 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec105k P-Amplitude positive, V5 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec105j P-Amplitude positive, V4 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec105i P-Amplitude positive, V3 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec105h P-Amplitude positive, V2 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec105g P-Amplitude positive, V1 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec105c P-Amplitude positive, III Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec105b P-Amplitude positive, II Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec105a P-Amplitude positive, I Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec106d P-Amplitude negative, aVR Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec106e P-Amplitude negative, aVL Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec106f P-Amplitude negative, aVF Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec106l P-Amplitude negative, V6 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec106k P-Amplitude negative, V5 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec106j P-Amplitude negative, V4 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec106i P-Amplitude negative, V3 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec106h P-Amplitude negative, V2 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec106g P-Amplitude negative, V1 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec106c P-Amplitude negative, III Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec106b P-Amplitude negative, II Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec106a P-Amplitude negative, I Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec150c7 Overturned right type Token «overturned right type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150c6 Overturned left type Token «overturned left type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ac2 Otherwise normal EKG Token «otherwise normal EKG» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec148 Original Customed Version Original version of Custo Software at the time of the ECG exam acquisition Categorical
ECG 10s (CHRIS baseline) x0ec150ab11 Note: Channel 'aVL' cannot be measured Token «Note: Channel 'aVL' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab10 Note: Channel 'aVF' cannot be measured Token «Note: Channel 'aVF' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab9 Note: Channel 'V5' cannot be measured Token «Note: Channel 'V5' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab8 Note: Channel 'V4' cannot be measured Token «Note: Channel 'V4' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab7 Note: Channel 'V3' cannot be measured Token «Note: Channel 'V3' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab6 Note: Channel 'V2' cannot be measured Token «Note: Channel 'V2' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab5 Note: Channel 'V1' cannot be measured Token «Note: Channel 'V1' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab4 Note: Channel 'III' cannot be measured Token «Note: Channel 'III' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab3 Note: Channel 'II' cannot be measured Token «Note: Channel 'II' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab2 Note: Channel 'I' cannot be measured Token «Note: Channel 'I' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150a5 Normofrequency sinus rhythm with sinus arrhythmia Token «normofrequency sinus rhythm with sinus arrhythmia» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150a4 Normofrequency sinus rhythm Token «normofrequency sinus rhythm» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150c1 Normal type Token «Normal type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ac1 Normal EKG Token «normal EKG» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150o1 Non-specific broadened P wave Token «non-specific broadened P wave» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec143d Noise, aVR Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec143e Noise, aVL Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec143f Noise, aVF Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec143l Noise, V6 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec143k Noise, V5 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec143j Noise, V4 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec143i Noise, V3 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec143h Noise, V2 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec143g Noise, V1 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec143c Noise, III Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec143b Noise, II Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec143a Noise, I Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec150ab1 No further interpretation was possible, since no sum complex could be created Token «No further interpretation was possible, since no sum complex could be created» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec139d Negative percentage of T-wave-area, aVR Negative percentage of T-wave-area in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec139e Negative percentage of T-wave-area, aVL Negative percentage of T-wave-area in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec139f Negative percentage of T-wave-area, aVF Negative percentage of T-wave-area in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec139l Negative percentage of T-wave-area, V6 Negative percentage of T-wave-area in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec139k Negative percentage of T-wave-area, V5 Negative percentage of T-wave-area in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec139j Negative percentage of T-wave-area, V4 Negative percentage of T-wave-area in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec139i Negative percentage of T-wave-area, V3 Negative percentage of T-wave-area in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec139h Negative percentage of T-wave-area, V2 Negative percentage of T-wave-area in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec139g Negative percentage of T-wave-area, V1 Negative percentage of T-wave-area in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec139c Negative percentage of T-wave-area, III Negative percentage of T-wave-area in lead III Integer
ECG 10s (CHRIS baseline) x0ec139b Negative percentage of T-wave-area, II Negative percentage of T-wave-area in lead II Integer
ECG 10s (CHRIS baseline) x0ec139a Negative percentage of T-wave-area, I Negative percentage of T-wave-area in lead I Integer