Variables

4291 variables.
Clear
Module Label Name Description Type
ECG 10s (CHRIS baseline) x0ec150h1 3 ventricular couplets Token «3 ventricular couplets» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150g1 2 monotopic PVCs Token «2 monotopic PVCs» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec105i P-Amplitude positive, V3 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec150f1 1st degree AV block Token «1st degree AV block» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150e3 3 SVES Token «3 SVES» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec105j P-Amplitude positive, V4 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec150e2 2 SVES Token «2 SVES» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150e1 1 SVES Token «1 SVES» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150d5 4 polytopic VES Token «4 polytopic VES» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150d4 2 polytopic VES Token «2 polytopic VES» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec101 Heart Rate, Resting Heart Rate at rest, expressed in beat-per-minute Integer
ECG 10s (CHRIS baseline) x0ec150c7 Overturned right type Token «overturned right type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec105d P-Amplitude positive, aVR Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec150c5 Steep type Token «Steep type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec105g P-Amplitude positive, V1 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec150c6 Overturned left type Token «overturned left type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec105f P-Amplitude positive, aVF Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec150c4 Sagittal type Token «Sagittal type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec105c P-Amplitude positive, III Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec150c3 Right type Token «Right type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150c2 Left type Token «Left type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150c1 Normal type Token «Normal type» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec105b P-Amplitude positive, II Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec150b4 Atrial fibrillation with variable conduction Token «Atrial fibrillation with variable conduction» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150b3 Atrial fibrillation with tachycardiac conduction Token «Atrial fibrillation with tachycardiac conduction» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec104k Duration P Wave, V5 Duration of P Wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec150b2 Atrial fibrillation with normofrequency conduction Token «Atrial fibrillation with normofrequency conduction» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ac2 Otherwise normal EKG Token «otherwise normal EKG» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec104l Duration P Wave, V6 Duration of P Wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec150ac1 Normal EKG Token «normal EKG» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab9 Note: Channel 'V5' cannot be measured Token «Note: Channel 'V5' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab8 Note: Channel 'V4' cannot be measured Token «Note: Channel 'V4' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab7 Note: Channel 'V3' cannot be measured Token «Note: Channel 'V3' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec104j Duration P Wave, V4 Duration of P Wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec135h JTc-Time, V2 Duration of JT interval corrected for the heart rate, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec150ab6 Note: Channel 'V2' cannot be measured Token «Note: Channel 'V2' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec136 Axis T Wave Average direction of the heart vector during electrical repolarization of the ventricles, expressed in degree Integer
ECG 10s (CHRIS baseline) x0ec150ab5 Note: Channel 'V1' cannot be measured Token «Note: Channel 'V1' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec138e Positive percentage of T-wave-area, aVL Positive percentage of T-wave-area in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec104i Duration P Wave, V3 Duration of P Wave, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec104g Duration P Wave, V1 Duration of P Wave, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec150ab4 Note: Channel 'III' cannot be measured Token «Note: Channel 'III' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150ab3 Note: Channel 'II' cannot be measured Token «Note: Channel 'II' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec139a Negative percentage of T-wave-area, I Negative percentage of T-wave-area in lead I Integer
ECG 10s (CHRIS baseline) x0ec139b Negative percentage of T-wave-area, II Negative percentage of T-wave-area in lead II Integer
ECG 10s (CHRIS baseline) x0ec140 Dispersion peak till end of T-Wave It is defined as the difference between the longest and the shortest peak-to-end of the T wave measured in the 12 ECG leads, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec127d Duration S' wave, aVR Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec150ab2 Note: Channel 'I' cannot be measured Token «Note: Channel 'I' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec127e Duration S' wave, aVL Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec104e Duration P Wave, aVL Duration of P Wave, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec150ab11 Note: Channel 'aVL' cannot be measured Token «Note: Channel 'aVL' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec126d S-Amplitude, aVR Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec128i S'-Amplitude, V3 Voltage amplitude of the peak of S wave in the first derivative of ECG, expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec123h R'-Amplitude, V2 Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec150ab10 Note: Channel 'aVF' cannot be measured Token «Note: Channel 'aVF' cannot be measured» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec123l R'-Amplitude, V6 Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec150aa9 Negative T wave in channel V5 Token «negative T wave in channel V5» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec104d Duration P Wave, aVR Duration of P Wave, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec125c Duration S wave, III Duration of S wave, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec115f QT Time, aVF Duration of QT interval, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec150aa7 Negative T wave in channel V3 Token «negative T wave in channel V3» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec120g Duration R wave, V1 Duration of R wave, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec150aa6 Negative T wave in channel V2 Token «negative T wave in channel V2» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec115b QT Time, II Duration of QT interval, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec121i R-Amplitude, V3 Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec104c Duration P Wave, III Duration of P Wave, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec110c Q-Amplitude, III Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec143g Noise, V1 Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec150d2 3 monotopic VES Token «3 monotopic VES» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec112 QRS-Dispersion QRS dispersion is defined as the difference between the longest and the shortest QRS complex measured in the 12 ECG leads, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec122e Duration R' wave, aVL Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec129j ST Value, V4 ST segment deviation from the isoelectric line, defined as the difference between the voltage value at the beginning of T wave and the end of S wave (J point) expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec150aa4 Negative T wave in channel aVL Token «negative T wave in channel aVL» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150aa3 Negative T wave in channel III Token «negative T wave in channel III» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec106j P-Amplitude negative, V4 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec108h PQ Time, V2 Duration of PQ interval, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec104h Duration P Wave, V2 Duration of P Wave, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec150aa2 Negative T wave in channel II Token «negative T wave in channel II» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150aa10 Negative T wave in channel V6 Token «negative T wave in channel V6» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec105h P-Amplitude positive, V2 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec109i Duration Q wave, V3 Duration of Q wave, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec150aa1 Negative T wave in channel I Token «negative T wave in channel I» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150a7 Tachycardiac sinus rhythm with sinus arrhythmia Token «tachycardiac sinus rhythm with sinus arrhythmia» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec102 Axis P Wave Average direction of the heart vector during electrical depolarization of the atria, expressed in degree Integer
ECG 10s (CHRIS baseline) x0ec150a5 Normofrequency sinus rhythm with sinus arrhythmia Token «normofrequency sinus rhythm with sinus arrhythmia» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec104b Duration P Wave, II Duration of P Wave, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec150a6 Tachycardiac sinus rhythm Token «tachycardiac sinus rhythm» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec104a Duration P Wave, I Duration of P Wave, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec104f Duration P Wave, aVF Duration of P Wave, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec110b Q-Amplitude, II Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec131h J-Value, V2 J point voltage value, expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec143b Noise, II Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec150a4 Normofrequency sinus rhythm Token «normofrequency sinus rhythm» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150a2 Bradycardic sinus rhythm Token «bradycardic sinus rhythm» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150a1 Bradycardic rhythm Token «bradycardic rhythm» is present in automated diagnosis Boolean
ECG 10s (CHRIS baseline) x0ec150 Automatic diagnosis in English Automatic diagnosis with main findings, given by the software, translated into English Character
ECG 10s (CHRIS baseline) x0ec149 Automatic diagnosis by the software Automatic diagnosis with main findings, given by the software Character
ECG 10s (CHRIS baseline) x0ec148 Original Customed Version Original version of Custo Software at the time of the ECG exam acquisition Categorical
ECG 10s (CHRIS baseline) x0ec145 Heart axis type Heart axis type Categorical
ECG 10s (CHRIS baseline) x0ec146 Heart rate as RR Heart rate expressed as RR interval, expressed in milliseconds Integer