Variables

4291 variables.
Clear
Module Label Name Description Type
ECG 10s (CHRIS baseline) x0ec141j Duration peak till end of T-Wave, V4 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec141k Duration peak till end of T-Wave, V5 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec141l Duration peak till end of T-Wave, V6 Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec146 Heart rate as RR Heart rate expressed as RR interval, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec151b QTc (Baz) Dispersion QTc interval dispersion is defined as the difference between the longest and the shortest QT interval duration (with Bazett formula) measured in the 12 ECG leads, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec152 QTc (Frid) Time Duration of QT interval adjusted for a standard heart-rate of 60bpm with Fridericia formula, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec152a QTc (Frid) Time, I Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec152b QTc (Frid) Time, II Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec152c QTc (Frid) Time, III Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec152d QTc (Frid) Time, aVR Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec127l Duration S' wave, V6 Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec127k Duration S' wave, V5 Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec127j Duration S' wave, V4 Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec127h Duration S' wave, V2 Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec127g Duration S' wave, V1 Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec127f Duration S' wave, aVF Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec125b Duration S wave, II Duration of S wave, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec127c Duration S' wave, III Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec127b Duration S' wave, II Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec127a Duration S' wave, I Duration S wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec152e QTc (Frid) Time, aVL Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec152f QTc (Frid) Time, aVF Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec152g QTc (Frid) Time, V1 Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec152h QTc (Frid) Time, V2 Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec152i QTc (Frid) Time, V3 Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec152j QTc (Frid) Time, V4 Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec152k QTc (Frid) Time, V5 Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec152l QTc (Frid) Time, V6 Duration of QT interval adjusted for the heart-rate with Fridericia formula, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec125l Duration S wave, V6 Duration of S wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec125k Duration S wave, V5 Duration of S wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec125j Duration S wave, V4 Duration of S wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec125i Duration S wave, V3 Duration of S wave, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec125h Duration S wave, V2 Duration of S wave, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec125g Duration S wave, V1 Duration of S wave, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec125f Duration S wave, aVF Duration of S wave, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec125e Duration S wave, aVL Duration of S wave, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec125d Duration S wave, aVR Duration of S wave, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec125a Duration S wave, I Duration of S wave, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec153 QTc (Baz) Time Duration of QT interval adjusted for a standard heart-rate of 60bpm with Bazett formula, expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec122a Duration R' wave, I Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec153a QTc (Baz) Time, I Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec153b QTc (Baz) Time, II Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec153c QTc (Baz) Time, III Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec153d QTc (Baz) Time, aVR Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec153g QTc (Baz) Time, V1 Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec153i QTc (Baz) Time, V3 Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec153j QTc (Baz) Time, V4 Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec122l Duration R' wave, V6 Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec122k Duration R' wave, V5 Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec122j Duration R' wave, V4 Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec122i Duration R' wave, V3 Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec122h Duration R' wave, V2 Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec122g Duration R' wave, V1 Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec122f Duration R' wave, aVF Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec122d Duration R' wave, aVR Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec122c Duration R' wave, III Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec122b Duration R' wave, II Duration R wave in the first derivative of the ECG wave, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec153l QTc (Baz) Time, V6 Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec153k QTc (Baz) Time, V5 Duration of QT interval adjusted for the heart-rate with Bazett formula, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec120l Duration R wave, V6 Duration of R wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec120k Duration R wave, V5 Duration of R wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec120j Duration R wave, V4 Duration of R wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec120i Duration R wave, V3 Duration of R wave, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec120h Duration R wave, V2 Duration of R wave, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec120f Duration R wave, aVF Duration of R wave, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec120e Duration R wave, aVL Duration of R wave, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec120d Duration R wave, aVR Duration of R wave, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec120c Duration R wave, III Duration of R wave, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec120b Duration R wave, II Duration of R wave, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec120a Duration R wave, I Duration of R wave, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec115l QT Time, V6 Duration of QT interval, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec115k QT Time, V5 Duration of QT interval, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec115j QT Time, V4 Duration of QT interval, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec115i QT Time, V3 Duration of QT interval, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec115h QT Time, V2 Duration of QT interval, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec115g QT Time, V1 Duration of QT interval, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec115e QT Time, aVL Duration of QT interval, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec115d QT Time, aVR Duration of QT interval, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec115a QT Time, I Duration of QT interval, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec115 QT Time Duration of QT interval (from the beginning of the Q wave to the end of the T wave), expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec113l QRS Duration, V6 Duration of QRS complex, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec113k QRS Duration, V5 Duration of QRS complex, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec113j QRS Duration, V4 Duration of QRS complex, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec113i QRS Duration, V3 Duration of QRS complex, expressed in milliseconds, measured in lead V3 Integer
ECG 10s (CHRIS baseline) x0ec113h QRS Duration, V2 Duration of QRS complex, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec113g QRS Duration, V1 Duration of QRS complex, expressed in milliseconds, measured in lead V1 Integer
ECG 10s (CHRIS baseline) x0ec113f QRS Duration, aVF Duration of QRS complex, expressed in milliseconds, measured in lead aVF Integer
ECG 10s (CHRIS baseline) x0ec113e QRS Duration, aVL Duration of QRS complex, expressed in milliseconds, measured in lead aVL Integer
ECG 10s (CHRIS baseline) x0ec113d QRS Duration, aVR Duration of QRS complex, expressed in milliseconds, measured in lead aVR Integer
ECG 10s (CHRIS baseline) x0ec113c QRS Duration, III Duration of QRS complex, expressed in milliseconds, measured in lead III Integer
ECG 10s (CHRIS baseline) x0ec113b QRS Duration, II Duration of QRS complex, expressed in milliseconds, measured in lead II Integer
ECG 10s (CHRIS baseline) x0ec113a QRS Duration, I Duration of QRS complex, expressed in milliseconds, measured in lead I Integer
ECG 10s (CHRIS baseline) x0ec113 QRS Duration Duration of QRS complex (from the beginning of the Q wave to the end of the S wave), expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec111 Axis QRS Average direction of the heart vector during electrical depolarization of the ventricles, expressed in degree Integer
ECG 10s (CHRIS baseline) x0ec108 PQ Time Duration of PQ interval (from the beginning of the P wave to the beginning of the QRS complex), expressed in milliseconds Integer
ECG 10s (CHRIS baseline) x0ec109l Duration Q wave, V6 Duration of Q wave, expressed in milliseconds, measured in lead V6 Integer
ECG 10s (CHRIS baseline) x0ec109k Duration Q wave, V5 Duration of Q wave, expressed in milliseconds, measured in lead V5 Integer
ECG 10s (CHRIS baseline) x0ec109j Duration Q wave, V4 Duration of Q wave, expressed in milliseconds, measured in lead V4 Integer
ECG 10s (CHRIS baseline) x0ec109h Duration Q wave, V2 Duration of Q wave, expressed in milliseconds, measured in lead V2 Integer
ECG 10s (CHRIS baseline) x0ec109g Duration Q wave, V1 Duration of Q wave, expressed in milliseconds, measured in lead V1 Integer