Variables

4291 variables.
Clear
Module Label Name Description Type
ECG 10s (CHRIS baseline) x0ec126g S-Amplitude, V1 Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec126f S-Amplitude, aVF Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec126e S-Amplitude, aVL Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec126c S-Amplitude, III Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec126b S-Amplitude, II Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec126a S-Amplitude, I Voltage amplitude of the peak of S wave, expressed in milliVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec124b Median of RR-Intervals Median of RR-Intervals (computed over the customed beat series), expressed in milliseconds Float
ECG 10s (CHRIS baseline) x0ec124a Mean of RR-Intervals Mean of RR-Intervals (computed over the customed beat series), expressed in milliseconds Float
ECG 10s (CHRIS baseline) x0ec123k R'-Amplitude, V5 Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec123j R'-Amplitude, V4 Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec123i R'-Amplitude, V3 Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec123g R'-Amplitude, V1 Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec123f R'-Amplitude, aVF Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec123e R'-Amplitude, aVL Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead aVL Float
Targeted serum metabolomics (CHRIS baseline) x0pt164 SM (OH) C22:1 Hydroxysphingomyeline C22:1 Float
ECG 10s (CHRIS baseline) x0ec123d R'-Amplitude, aVR Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec123c R'-Amplitude, III Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec123b R'-Amplitude, II Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec123a R'-Amplitude, I Voltage amplitude of the peak of R wave in the first derivative of ECG, expressed in milliVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec121l R-Amplitude, V6 Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec121k R-Amplitude, V5 Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec121j R-Amplitude, V4 Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec121h R-Amplitude, V2 Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec121g R-Amplitude, V1 Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec121f R-Amplitude, aVF Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec121e R-Amplitude, aVL Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec121d R-Amplitude, aVR Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec121c R-Amplitude, III Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec121b R-Amplitude, II Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec121a R-Amplitude, I Voltage amplitude of the peak of R wave, expressed in milliVolts, measured in lead I Float
Targeted serum metabolomics (CHRIS baseline) x0pt165 SM (OH) C22:2 Hydroxysphingomyeline C22:2 Float
Targeted serum metabolomics (CHRIS baseline) x0pt166 SM (OH) C24:1 Hydroxysphingomyeline C24:1 Float
Targeted serum metabolomics (CHRIS baseline) x0pt167 SM C16:0 Sphingomyeline C16:0 Float
ECG 10s (CHRIS baseline) x0ec110l Q-Amplitude, V6 Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec110k Q-Amplitude, V5 Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec110j Q-Amplitude, V4 Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec110i Q-Amplitude, V3 Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec110h Q-Amplitude, V2 Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec110g Q-Amplitude, V1 Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec110f Q-Amplitude, aVF Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec110e Q-Amplitude, aVL Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec110d Q-Amplitude, aVR Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec110a Q-Amplitude, I Voltage amplitude of the peak of Q wave, expressed in milliVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec106l P-Amplitude negative, V6 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec106k P-Amplitude negative, V5 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec106i P-Amplitude negative, V3 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec106h P-Amplitude negative, V2 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V2 Float
ECG 10s (CHRIS baseline) x0ec106g P-Amplitude negative, V1 Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec106f P-Amplitude negative, aVF Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec106e P-Amplitude negative, aVL Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec106d P-Amplitude negative, aVR Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec106c P-Amplitude negative, III Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec106b P-Amplitude negative, II Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead II Float
ECG 10s (CHRIS baseline) x0ec106a P-Amplitude negative, I Peak amplitude of the negative deflection of P wave, expressed in milliVolts, measured in lead I Float
ECG 10s (CHRIS baseline) x0ec105l P-Amplitude positive, V6 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V6 Float
ECG 10s (CHRIS baseline) x0ec105k P-Amplitude positive, V5 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V5 Float
ECG 10s (CHRIS baseline) x0ec105j P-Amplitude positive, V4 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V4 Float
ECG 10s (CHRIS baseline) x0ec105i P-Amplitude positive, V3 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V3 Float
ECG 10s (CHRIS baseline) x0ec105g P-Amplitude positive, V1 Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead V1 Float
ECG 10s (CHRIS baseline) x0ec105f P-Amplitude positive, aVF Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead aVF Float
ECG 10s (CHRIS baseline) x0ec105e P-Amplitude positive, aVL Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead aVL Float
ECG 10s (CHRIS baseline) x0ec105d P-Amplitude positive, aVR Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead aVR Float
ECG 10s (CHRIS baseline) x0ec105c P-Amplitude positive, III Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead III Float
ECG 10s (CHRIS baseline) x0ec105b P-Amplitude positive, II Peak amplitude of the positive deflection of P wave, expressed in milliVolts, measured in lead II Float
Alcohol (CHRIS baseline) x0al10 Daily alcohol intake (last 12 months) Daily alcohol intake (continuous) Float
Blood pressure (CHRIS baseline) x0bp18c Time of 3rd blood pressure measurement, CNAP Time since measurement start, 3rd measurement Float
Blood pressure (CHRIS baseline) x0bp18b Time of 2nd blood pressure measurement, CNAP Time since measurement start, 2nd measurement Float
Blood pressure (CHRIS baseline) x0bp18a Time of 1st blood pressure measurement, CNAP Time since measurement start, 1st measurement Float
Blood pressure (CHRIS baseline) x0bp13 Pulse, CNAP Pulse (mean over ECG 20 min) Float
Heart rate variability (CHRIS baseline) x0ec283t MSE (t=20) MSE (t=20): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 20 Float
Heart rate variability (CHRIS baseline) x0ec283s MSE (t=19) MSE (t=19): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 19 Float
Heart rate variability (CHRIS baseline) x0ec283r MSE (t=18) MSE (t=18): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 18 Float
Heart rate variability (CHRIS baseline) x0ec283q MSE (t=17) MSE (t=17): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 17 Float
Heart rate variability (CHRIS baseline) x0ec283p MSE (t=16) MSE (t=16): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 16 Float
Heart rate variability (CHRIS baseline) x0ec283o MSE (t=15) MSE (t=15): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 15 Float
Heart rate variability (CHRIS baseline) x0ec283n MSE (t=14) MSE (t=14): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 14 Float
Heart rate variability (CHRIS baseline) x0ec283m MSE (t=13) MSE (t=13): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 13 Float
Heart rate variability (CHRIS baseline) x0ec283l MSE (t=12) MSE (t=12): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 12 Float
Heart rate variability (CHRIS baseline) x0ec283k MSE (t=11) MSE (t=11): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 11 Float
Heart rate variability (CHRIS baseline) x0ec283i MSE (t=9) MSE (t=9): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 9 Float
Heart rate variability (CHRIS baseline) x0ec283h MSE (t=8) MSE (t=8): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 8 Float
Heart rate variability (CHRIS baseline) x0ec283g MSE (t=7) MSE (t=7): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 7 Float
Heart rate variability (CHRIS baseline) x0ec283f MSE (t=6) MSE (t=6): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 6 Float
Heart rate variability (CHRIS baseline) x0ec283e MSE (t=5) MSE (t=5): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 5 Float
Heart rate variability (CHRIS baseline) x0ec283d MSE (t=4) MSE (t=4): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 4 Float
Heart rate variability (CHRIS baseline) x0ec283c MSE (t=3) MSE (t=3): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 3 Float
Heart rate variability (CHRIS baseline) x0ec283b MSE (t=2) MSE (t=2): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 2 Float
Heart rate variability (CHRIS baseline) x0ec283a MSE (t=1) MSE (t=1): Multi Scale Entropy, extension of SampEn to multiple time scales, here calculated for time scale factor equal to 1 Float
Heart rate variability (CHRIS baseline) x0ec282 RPA Shannon Entropy RPA Shannon Entropy: it is the entropy of the probability distribution of the diagonal line lengths Float
Heart rate variability (CHRIS baseline) x0ec261 VLF power (%) (AR) Relative power of VLF band, with PSD estimated using parametric autoregressive (AR) modeling method, expressed in ms^2 Float
Blood pressure (CHRIS baseline) x0bp12 Diastolic blood pressure, CNAP Diastolic blood pressure (mean of 3 measurements) Float
Heart rate variability (CHRIS baseline) x0ec279 RPA divergence RPA divergence: Recurrence Plot Analysis is another approach for analyzing the complexity of the RR series, which consists in creating a symmetrical matrix of zeros and ones. The divergence (DIV) is defined as the inverse of Lmax Float
Heart rate variability (CHRIS baseline) x0ec278 RPA determinism RPA determinism: Recurrence Plot Analysis is another approach for analyzing the complexity of the RR series, which consists in creating a symmetrical matrix of zeros and ones. The determinism (DET) is defined as the percentage of recurrence points which form diagonal lines Float
Heart rate variability (CHRIS baseline) x0ec277 RPA recurrence rate RPA recurrence rate: Recurrence Plot Analysis is another approach for analyzing the complexity of the RR series, which consists in creating a symmetrical matrix of zeros and ones. The recurrence rate (REC) is defined as the ratio of ones and zeros in this RP matrix Float
Heart rate variability (CHRIS baseline) x0ec276 DFA alpha2 DFA alpha2: Detrended Fluctuation Analysis measures the correlation within the signal. Slope alpha2 characterizes long-term fluctuations or the RR series Float
Heart rate variability (CHRIS baseline) x0ec275 DFA alpha1 DFA alpha1: Detrended Fluctuation Analysis measures the correlation within the signal. Slope alpha1 characterizes short-term fluctuations or the RR series Float
Heart rate variability (CHRIS baseline) x0ec273 Sample Entropy Sample Entropy: similar to ApEn, but it presents some differences in the calculation Float
Heart rate variability (CHRIS baseline) x0ec272 Approximate Entropy Approximate Entropy: measures the complexity or irregularity of the signal. Large values of ApEn indicate high irregularity and smaller values of ApEn more regular signal Float
Heart rate variability (CHRIS baseline) x0ec270 Poincare SD2/SD1 Poincare SD2/SD1: ratio between SD2 and SD1 Float
Heart rate variability (CHRIS baseline) x0ec269 Poincare SD2 Poincare SD2: in Poincare plot, SD2 represents the standard deviation along the line-of-identity Float