ECG 10s (CHRIS baseline)

md_x0_0015

10-second resting ECG performed at the study center

Negative percentage of T-wave-area, aVF

Negative percentage of T-wave-area in lead aVF

x0ec139f
Negative percentage of T-wave-area, V1

Negative percentage of T-wave-area in lead V1

x0ec139g
Negative percentage of T-wave-area, V2

Negative percentage of T-wave-area in lead V2

x0ec139h
Negative percentage of T-wave-area, V3

Negative percentage of T-wave-area in lead V3

x0ec139i
Negative percentage of T-wave-area, V4

Negative percentage of T-wave-area in lead V4

x0ec139j
Negative percentage of T-wave-area, V5

Negative percentage of T-wave-area in lead V5

x0ec139k
Negative percentage of T-wave-area, V6

Negative percentage of T-wave-area in lead V6

x0ec139l
Dispersion peak till end of T-Wave

It is defined as the difference between the longest and the shortest peak-to-end of the T wave measured in the 12 ECG leads, expressed in milliseconds

x0ec140
Duration peak till end of T-Wave, I

Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead I

x0ec141a
Duration peak till end of T-Wave, II

Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead II

x0ec141b
Duration peak till end of T-Wave, III

Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead III

x0ec141c
Duration peak till end of T-Wave, aVR

Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead aVR

x0ec141d
Duration peak till end of T-Wave, aVL

Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead aVL

x0ec141e
Duration peak till end of T-Wave, aVF

Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead aVF

x0ec141f
Duration peak till end of T-Wave, V1

Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V1

x0ec141g
Duration peak till end of T-Wave, V2

Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V2

x0ec141h
Duration peak till end of T-Wave, V3

Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V3

x0ec141i
Duration peak till end of T-Wave, V4

Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V4

x0ec141j
Duration peak till end of T-Wave, V5

Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V5

x0ec141k
Duration peak till end of T-Wave, V6

Time interval between the peak up to the end of T wave, expressed in milliseconds, measured in lead V6

x0ec141l
Sokolow-Index

Sokolow-Index index for left ventricular hypertrophy, calculated as the sum of the amplitudes of the S wave in V1 and the R wave in V5 or V6 (whichever is larger), expressed in milliVolts [https://doi.org/10.1016/0002-8703(49)90562-1]

x0ec142
Noise, I

Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead I

x0ec143a
Noise, II

Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead II

x0ec143b
Noise, III

Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead III

x0ec143c
Noise, aVR

Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVR

x0ec143d
Noise, aVL

Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVL

x0ec143e
Noise, aVF

Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead aVF

x0ec143f
Noise, V1

Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V1

x0ec143g
Noise, V2

Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V2

x0ec143h
Noise, V3

Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V3

x0ec143i
Noise, V4

Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V4

x0ec143j
Noise, V5

Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V5

x0ec143k
Noise, V6

Noise level estimation, when QTc is computed with Fridericia formula, expressed in microVolts, measured in lead V6

x0ec143l
Heart axis type

Heart axis type

x0ec145
Heart rate as RR

Heart rate expressed as RR interval, expressed in milliseconds

x0ec146
Original Customed Version

Original version of Custo Software at the time of the ECG exam acquisition

x0ec148
Automatic diagnosis by the software

Automatic diagnosis with main findings, given by the software

x0ec149
Automatic diagnosis in English

Automatic diagnosis with main findings, given by the software, translated into English

x0ec150
Bradycardic rhythm

Token «bradycardic rhythm» is present in automated diagnosis

x0ec150a1
Bradycardic sinus rhythm

Token «bradycardic sinus rhythm» is present in automated diagnosis

x0ec150a2
Bradycardic sinus rhythm with sinus arrhythmia

Token «bradycardic sinus rhythm with sinus arrhythmia» is present in automated diagnosis

x0ec150a3
Normofrequency sinus rhythm

Token «normofrequency sinus rhythm» is present in automated diagnosis

x0ec150a4
Normofrequency sinus rhythm with sinus arrhythmia

Token «normofrequency sinus rhythm with sinus arrhythmia» is present in automated diagnosis

x0ec150a5
Tachycardiac sinus rhythm

Token «tachycardiac sinus rhythm» is present in automated diagnosis

x0ec150a6
Tachycardiac sinus rhythm with sinus arrhythmia

Token «tachycardiac sinus rhythm with sinus arrhythmia» is present in automated diagnosis

x0ec150a7
Negative T wave in channel I

Token «negative T wave in channel I» is present in automated diagnosis

x0ec150aa1
Negative T wave in channel V6

Token «negative T wave in channel V6» is present in automated diagnosis

x0ec150aa10
Negative T wave in channel II

Token «negative T wave in channel II» is present in automated diagnosis

x0ec150aa2
Negative T wave in channel III

Token «negative T wave in channel III» is present in automated diagnosis

x0ec150aa3
Negative T wave in channel aVL

Token «negative T wave in channel aVL» is present in automated diagnosis

x0ec150aa4
Negative T wave in channel aVF

Token «negative T wave in channel aVF» is present in automated diagnosis

x0ec150aa5
Negative T wave in channel V2

Token «negative T wave in channel V2» is present in automated diagnosis

x0ec150aa6
Negative T wave in channel V3

Token «negative T wave in channel V3» is present in automated diagnosis

x0ec150aa7
Negative T wave in channel V4

Token «negative T wave in channel V4» is present in automated diagnosis

x0ec150aa8
Negative T wave in channel V5

Token «negative T wave in channel V5» is present in automated diagnosis

x0ec150aa9
No further interpretation was possible, since no sum complex could be created

Token «No further interpretation was possible, since no sum complex could be created» is present in automated diagnosis

x0ec150ab1
Note: Channel 'aVF' cannot be measured

Token «Note: Channel 'aVF' cannot be measured» is present in automated diagnosis

x0ec150ab10
Note: Channel 'aVL' cannot be measured

Token «Note: Channel 'aVL' cannot be measured» is present in automated diagnosis

x0ec150ab11
Note: Channel 'I' cannot be measured

Token «Note: Channel 'I' cannot be measured» is present in automated diagnosis

x0ec150ab2
Note: Channel 'II' cannot be measured

Token «Note: Channel 'II' cannot be measured» is present in automated diagnosis

x0ec150ab3
Note: Channel 'III' cannot be measured

Token «Note: Channel 'III' cannot be measured» is present in automated diagnosis

x0ec150ab4
Note: Channel 'V1' cannot be measured

Token «Note: Channel 'V1' cannot be measured» is present in automated diagnosis

x0ec150ab5
Note: Channel 'V2' cannot be measured

Token «Note: Channel 'V2' cannot be measured» is present in automated diagnosis

x0ec150ab6
Note: Channel 'V3' cannot be measured

Token «Note: Channel 'V3' cannot be measured» is present in automated diagnosis

x0ec150ab7
Note: Channel 'V4' cannot be measured

Token «Note: Channel 'V4' cannot be measured» is present in automated diagnosis

x0ec150ab8
Note: Channel 'V5' cannot be measured

Token «Note: Channel 'V5' cannot be measured» is present in automated diagnosis

x0ec150ab9
Normal EKG

Token «normal EKG» is present in automated diagnosis

x0ec150ac1
Otherwise normal EKG

Token «otherwise normal EKG» is present in automated diagnosis

x0ec150ac2
Atrial fibrillation with bradycardic conduction

Token «Atrial fibrillation with bradycardic conduction» is present in automated diagnosis

x0ec150b1
Atrial fibrillation with normofrequency conduction

Token «Atrial fibrillation with normofrequency conduction» is present in automated diagnosis

x0ec150b2
Atrial fibrillation with tachycardiac conduction

Token «Atrial fibrillation with tachycardiac conduction» is present in automated diagnosis

x0ec150b3
Atrial fibrillation with variable conduction

Token «Atrial fibrillation with variable conduction» is present in automated diagnosis

x0ec150b4
Normal type

Token «Normal type» is present in automated diagnosis

x0ec150c1
Left type

Token «Left type» is present in automated diagnosis

x0ec150c2
Right type

Token «Right type» is present in automated diagnosis

x0ec150c3
Sagittal type

Token «Sagittal type» is present in automated diagnosis

x0ec150c4
Steep type

Token «Steep type» is present in automated diagnosis

x0ec150c5
Overturned left type

Token «overturned left type» is present in automated diagnosis

x0ec150c6
Overturned right type

Token «overturned right type» is present in automated diagnosis

x0ec150c7
1 VES

Token «1 VES» is present in automated diagnosis

x0ec150d1
3 monotopic VES

Token «3 monotopic VES» is present in automated diagnosis

x0ec150d2
4 monotopic VES

Token «4 monotopic VES» is present in automated diagnosis

x0ec150d3
2 polytopic VES

Token «2 polytopic VES» is present in automated diagnosis

x0ec150d4
4 polytopic VES

Token «4 polytopic VES» is present in automated diagnosis

x0ec150d5
1 SVES

Token «1 SVES» is present in automated diagnosis

x0ec150e1
2 SVES

Token «2 SVES» is present in automated diagnosis

x0ec150e2
3 SVES

Token «3 SVES» is present in automated diagnosis

x0ec150e3
4 SVES

Token «4 SVES» is present in automated diagnosis

x0ec150e4
1st degree AV block

Token «1st degree AV block» is present in automated diagnosis

x0ec150f1
2 monotopic PVCs

Token «2 monotopic PVCs» is present in automated diagnosis

x0ec150g1
3 ventricular couplets

Token «3 ventricular couplets» is present in automated diagnosis

x0ec150h1
2nd degree AV block

Token «2nd degree AV block» is present in automated diagnosis

x0ec150i1
Mobitz type

Token «Mobitz type» is present in automated diagnosis

x0ec150i2
Wenckebach type

Token «Wenckebach type» is present in automated diagnosis

x0ec150i3
Right bundle branch block

Token «Right bundle branch block» is present in automated diagnosis

x0ec150j1
Incomplete right bundle branch block

Token «incomplete right bundle branch block» is present in automated diagnosis

x0ec150j2
Left bundle branch block

Token «Left bundle branch block» is present in automated diagnosis

x0ec150k1
Left bundle branch block possible

Token «Left bundle branch block possible» is present in automated diagnosis

x0ec150k2
Left anterior hemiblock

Token «left anterior hemiblock» is present in automated diagnosis

x0ec150l1
Left ventricular hypertrophy

Token «left ventricular hypertrophy» is present in automated diagnosis

x0ec150m1
No documents.
Single tokens extracted from free-text diagnosis of Customed Software in 10s resting ECG

137 variables.
Original version of Custo Software when the 10s resting ECG was recorded

1 variables.
Dispersion measurements in 10s resting ECG

9 variables.
Heart Axis angles in 10s resting ECG

4 variables.
Measurments related to lead I in the 10s resting ECG

28 variables.
Measurments related to lead II in the 10s resting ECG

28 variables.
Measurments related to lead III in the 10s resting ECG

28 variables.
Measurements related to JT interval in 10s resting ECG

14 variables.
Measurements related to JT corrected interval in 10s resting ECG

14 variables.
Measurements related to J point in 10s resting ECG

25 variables.
Noise level estimation in 10s resting ECG

12 variables.
Measurements related to PQ interval in 10s resting ECG

14 variables.
Measurements related to P wave in 10s resting ECG

39 variables.
Measurements related to QRS complex in 10s resting ECG

15 variables.
Measurements related to QT interval in 10s resting ECG

14 variables.
Measurements related to QT interval corrected with Bazett formula in 10s resting ECG

14 variables.
Measurements related to QT interval corrected with Fridericia formula in 10s resting ECG

14 variables.
Measurements related to Q wave in 10s resting ECG

24 variables.
RR series statistics in 10s resting ECG

4 variables.
Measurements related to R wave in 10s resting ECG

48 variables.
Measurements related to ST segment in 10s resting ECG

12 variables.
Measurements related to S wave in 10s resting ECG

48 variables.
Summary measurements in 10s resting ECG

16 variables.
Measurements related to T wave in 10s resting ECG

50 variables.
Measurments related to lead V1 in the 10s resting ECG

28 variables.
Measurments related to lead V2 in the 10s resting ECG

28 variables.
Measurments related to lead V3 in the 10s resting ECG

28 variables.
Measurments related to lead V4 in the 10s resting ECG

28 variables.
Measurments related to lead V5 in the 10s resting ECG

28 variables.
Measurments related to lead V6 in the 10s resting ECG

28 variables.
Measurments related to lead aVF in the 10s resting ECG

28 variables.
Measurments related to lead aVL in the 10s resting ECG

28 variables.
Measurments related to lead aVR in the 10s resting ECG

28 variables.